Skip to main content

Hardware_Model_Power.csv

note

If you are using the Technology Intelligence Platform version of IT Visibility’s export, information in this section is not applicable to you. Instead, see IT Visibility Data Export Using Technology Intelligence Platform. To check whether you are using Technology Intelligence Platform or Pre-Technology Intelligence Platform version, go to the Data Export page ( IT Visibility > Data Exports ). If you see two buttons for exporting—a Create Export button and a Create Export (Beta) button—you are using a Pre-Technology Intelligence Platform version (export version 1 or version 2). If you only see the Create Export button, you are either on the Technology Intelligence Platform version or export version 3. For related information, see Upgrading to the Export Version 3 of IT Visibility.

This file contains hardware model power information.

Column PositionColumn NameTypeColumn Description
1HardwareModelPowerIDUUIDThe unique identifier for hardware model power.
2HardwareModelIDUUIDThe HardwareModelID in Technopedia this Hardware Model Power record relates to.
3ACCurrentHighMinFloatManufacturer's suggested AC electrical input requirements: The minimum current when the voltage switch is turned on to the high range setting.
4ACCurrentHighMaxFloatManufacturer's suggested AC electrical input requirements: The maximum current when the voltage switch is turned on the high range setting.
5ACCurrentLowMinFloatManufacturer's suggested AC electrical input requirements: The minimum current when the voltage switch is turned on to the low range setting, or when the device has no voltage switch (single voltage range).
6ACCurrentLowMaxFloatManufacturer's suggested AC electrical input requirements: The maximum current when the voltage switch is turned on to the low range setting, or when the device has no voltage switch (single voltage range).
7ACFrequencyMinFloatThe manufacturer's suggested AC input requirements: The minimum frequency (whether the voltage switch is turned on low/high or when the device has no voltage switch).
8ACFrequencyMaxFloatThe manufacturer's suggested AC input requirements: The maximum frequency (whether the voltage switch is turned on low/high or when the device has no voltage switch).
9ACHeatDissipationAverageStringThe average amount of heat per-unit of time generated by the device during typical use when it is hooked up to AC power (in BTU/hr).
10ACHeatDissipationMaxStringThe peak or maximum amount of heat per-units of time generated by the device during typical usage when it is hooked up to AC power (in BTU/hr).
11ACPhaseInt64The phase of the AC.
12AcPowerAverageStringThe average amount of power (energy per-unit of time) consumed by the device during typical use when it is hooked up to AC power (in watt or volt-amp).
13ACPowerAverageUnitStringThe unit for AC_POWER_AVG column (watt or volt-amp).
14ACPowerMaxStringThe peak or maximum amount of power (energy per-unit of time) consumed by the device when it is hooked up to AC power (in watt or volt-amp).
15ACPowerMaxUnitStringThe unit for the AC_POWER_MAX column (watt or volt-amp).
16ACVoltageHighMinFloatManufacturer's suggested AC electrical input requirements: The minimum voltage when the voltage switch is turned to on the high range setting.
17ACVoltageHighMaxFloatManufacturer's suggested AC electrical input requirements: The maximum voltage when the voltage switch is turned on to the high range setting.
18ACVoltageLowMinFloatManufacturer's suggested AC electrical input requirements: The minimum voltage when the voltage switch is turned on to the low range setting, or when the device has no voltage switch (single voltage range).
19ACVoltageLowMaxFloatManufacturer's suggested AC electrical input requirements: The maximum voltage when the voltage switch is turned on to the low range setting, or when the device has no voltage switch (single voltage range) .
20BatteryLifeInt64Hours of possible battery life.
21BatteryTypeStringBattery type.
22DCCurrentLowFloatThe manufacturer's suggested DC input requirements: The current when the voltage switch is turned on the low setting or when the device has no voltage switch (single voltage).
23DCCurrentHighFloatThe manufacturer's suggested DC input requirements: The current when the voltage switch is turned on the high setting.
24DCHeatDissipationAverageStringThe average amount of heat per-unit of time generated by the device during typical use when it is hooked up to DC power (in BTU/hr).
25DCHeatDissipationMaxStringThe peak or maximum amount of heat per-unit of time generated by the device when it is hooked up to DC power (in BTU/hr).
26DCPowerAverageStringThe average amount of power (energy per-unit of time) consumed by the device during typical use when it is hooked up.
27DCPowerMaxStringThe peak or maximum amount of power (energy per-unit of time) consumed by the device when it is hooked up to DC power (in watt or volt-amp).
28DCVoltageLowFloatThe manufacturer's suggested DC input requirements: The voltage when the voltage switch is turned on the low setting or when the device has no voltage switch (single voltage).
29DCVoltageHighFloatThe manufacturer's suggested DC input requirement: The voltage when the voltage switch is turned on the high setting.
30EmergencyPowerStringListing of the emergency power.
31EpeatStringThis is a flag to indicate which EPEAT certification the device has earned: Gold, Silver, or Bronze.
32HasDedicatedCircuitStringListing of the dedicated circuit.
33IsEnergyStarStringThis is a flag to indicate whether the device has earned the Energy Star certification or not.
34NonOperatingHumidityMinFloatThe manufacturer's suggested minimum humidity (percentage) of the device when it is non-operational or in storage.
35NonOperatingHumidityMaxFloatThe manufacturer's suggested peak or maximum humidity (percentage) of the device when it is non-operational or in storage.
36NonOperatingTemperatureMinFloatThe manufacturer's suggested minimum temperature of the device when it is non-operational or in storage (in Fahrenheit).
37NonOperatingTemperatureMaxFloatThe manufacturer's suggested peak or maximum temperature of the device when it is non-operational or in storage (in Fahrenheit).
38OperatingHumidityMinFloatThe manufacturer's suggested minimum humidity (percentage) of the device during operation.
39OperatingHumidityMaxFloatThe manufacturer's suggested peak or maximum humidity (percentage) of the device during operation.
40OperatingTemperatureMinFloatThe manufacturer's suggested minimum temperature of the device during operation (in Fahrenheit).
41OperatingTemperatureMaxFloatThe manufacturer's suggested peak or maximum temperature of the device during operation (in Fahrenheit).
42PlugTypeStringPlug type (NEMA).
43PowerRatingStringThe summary of the device's various power ratings: Voltage, Frequency, and Current.
44CreatedDateStringThe date when an entry was first created.
45OrgIDStringThe unique identifier for the organization.